31-45 ANALIZA UNOR SISTEME CLASICE DE TELEMĂSURARE A NIVELULUI LICHIDELOR. SISTEME CU IMPULSURI DE C.C. ȘI CU LOGOMETRU DE NIVEL Partea I-a


ANALYSIS ON CLASSIC TELEMETRY SYSTEMS USED FOR LIQUID LEVEL. D.C. PULSES SYSTEMS AND LEVEL LOGOMETER – Part I

 

The paper presents an analysis of four classic telemetry systems for level measurement, i.e.: for three such systems with floating and counterweight, such as those with D.C. pulses, with potentiometer and a D.C. voltmeter, and two identical selsins, one transmitter and one receiver, and a resistive transducer system and logo meter level indicator, which is only used for liquids that have low resistivity. At the last system, it was made a study about linearized conversion, for liquid level in the angular displacement of the indicator.

 

Keywords: float level sensor, transducer resistive level gauge logometru, synchro

Cuvinte cheie: traductor de nivel cu plutitor, traductor rezistiv de nivel, logometru indicator de nivel, selsin

Descarcare text