35-81 ANALIZA FIABILITĂŢII STAŢIEI DE TRATARE A APEI GILĂU DIN SAA “SOMEŞ” CLUJ
RELIABILITY ANALYSIS OF THE WATER TREATMENT PLANT IN THE “SOMEŞ” SA CLUJ
ABSTRACT
The paper analyzes the reliability of the Gilau water treatment plant within the „Someş” water distribution system in Cluj, by implementing the modern method of analysis FMECA.
Following the assessment of the reliability and critical condition of the components of the treatment plant, appropriate measures have been identified that have led to a reduction in the degree of risk and the framing of most components in the area of risk acceptance. It also highlights the high risk elements that need to be further analyzed to reduce the risk, reduce the failure rate and increase operational safety.
Keywords: Water treatment plant, reliability analysis, FMECA procedure
Cuvinte cheie: Staţia de tratare a apei, analiza fiabilităţii, utilizarea metodei AMDEC.